The multi-stage pump is an ordinary general-purpose mechanical equipment and is widely used. However, the water pump sometimes suddenly fails to pump out water during use. So what are the reasons why the multi-stage pump cannot pump out water? The editor below will tell you the reasons why the multi-stage pump cannot pump water and how to deal with it.

Horizontal multi-stage water pump

     Reasons why the multi-stage pump cannot pump water and how to deal with it:

       1. The air in the multi-stage pump is not exhausted or the vacuum is not enough.

       Judgment Method:

  • Open the exhaust valve or exhaust bolt to see if there is air discharged;

  • Check the vacuum gauge to see if the reading is below -0.2mpa;

       Approach :

       a. Drain the air in the pump, check whether the water is diverted for irrigation, whether the pipes are leaking, and whether the packing leakage is too large;

       b. Check whether the pipeline is leaking, whether the packing is leaking, whether the vacuum pump is normal, and whether the water pressure of the jet air pump is normal;


       2. The inlet pipe is blocked and the bottom valve is blocked.

       Judgment Method:

  • The vacuum degree of the vacuum gauge reaches below -0.2;

  • When the exhaust valve or exhaust hole is opened, no liquid flows out;

       Treatment methods : 

Inspection, cleaning, pipeline filters, filters, foot valves, gate valves.


       3. The motor rotation direction is incorrect and the motor and pump are not connected.

       Judgment Method :

  • Jog the motor to see if the motor direction is consistent with the water pump;

  • Check whether the coupling pin is installed;

       Approach:

       a. Change the direction of motor rotation;

       b. Connect the coupling pin.


       4. The packing leaks and the mechanical seal leaks greatly, causing air leakage.

       Judgment Method : 

Check whether the packing is dry, whether the shaft sleeve is worn, 

and whether the mechanical seal is worn;

       Approach :

       a. Replace the packing or sleeve and apply butter on the packing;